首页 | 本学科首页   官方微博 | 高级检索  
     

蒸发冷却与机械制冷复合空调机组分析
引用本文:徐方成,黄翔,武俊梅. 蒸发冷却与机械制冷复合空调机组分析[J]. 建筑节能, 2008, 36(11)
作者姓名:徐方成  黄翔  武俊梅
作者单位:西安工程大学环境与化学工程学院,西安,710048
基金项目:西安工程大学创新基金资助项目
摘    要:对蒸发冷却与机械制冷复合空调机组进行了(火用)分析,并根据实测数据计算出了机组各功能段进出口(火用)的大小,并通过(火用)效率和(火用)效比分析得出了复合空调机组能量利用效率低的薄弱环节,提出了节能改进方法.

关 键 词:间接蒸发冷却  机械制冷  (火用)分析  (火用)效比

Exergy Analysis of Evaporative Cooling Assisting to Mechanical Refrigeration Air-conditioning Unit
XU FANG-cheng,HUANG Xiang,WU Jun-mei. Exergy Analysis of Evaporative Cooling Assisting to Mechanical Refrigeration Air-conditioning Unit[J]. Construction Conserves Energy, 2008, 36(11)
Authors:XU FANG-cheng  HUANG Xiang  WU Jun-mei
Abstract:The exergy conversion connection of evaporative cooling assisting to mechanical refrigeration air-conditioning unit was ana-lyzed,and every kind of exergy in exit and import of the unit was calculated according to practice test data.Through analysis of exergy effi-ciency and exergy efficiency ratiot,he result shows the weak points of low energy efficiency of air-conditioning unit,and the improved meth-ods of energy efficiency was put forward.
Keywords:IEC  mechanical refrigeration  exergy analysis  exergy efficiency ratio  
本文献已被 CNKI 维普 万方数据 等数据库收录!