首页 | 本学科首页   官方微博 | 高级检索  
     


Reliability Test of the 170GHz Gyrotron for ITER
Authors:Ken Kajiwara  Atsushi Kasugai  Yasuihisa Oda  Koji Takahashi  Keishi Sakamoto  Calorine Darbos  Mark Henderson
Affiliation:(1) Japan Atomic Energy Agency, 801-1 Mukoyama, Naka Ibaraki, 311-0193, Japan;(2) ITER Organization, CS 90 046, 13067 St Paul lez Durance Cedex, France
Abstract:Using the ITER relevant 170 GHz gyrotron, repetitive operation with long pulse and high power is conducted. The first consecutive days repetitive operation with ITER equivalent condition (800 kW/600 s with 20 min interval) is successfully performed in JAEA gyrotron test stand in order to obtain a basic data of the reliability of the current gyrotron system. Seventy-two shots out of 88 shots were successfully continued until the end of the pulse (600 s). The successful rate was 82%. The results demonstrate the feasibility of gyrotron operating at a high reliability for high power long pulse operation for ITER like conditions.
Keywords:
本文献已被 SpringerLink 等数据库收录!