首页 | 本学科首页   官方微博 | 高级检索  
     


Enhancement of stack ventilation in hot and humid climate using a combination of roof solar collector and vertical stack
Authors:Wardah Fatimah Mohammad Yusoff  Elias Salleh  Nor Mariah Adam  Abdul Razak Sapian  Mohamad Yusof Sulaiman
Affiliation:1. Department of Architecture, Faculty of Design and Architecture, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia;2. Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia;3. Department of Architecture, Kulliyyah of Architecture and Environmental Design, International Islamic University Malaysia, P.O. Box 10, 50728 Kuala Lumpur, Malaysia;4. Solar Energy Research Institute, 3rd Floor, Tun Sri Lanang Library Building, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
Abstract:In the hot and humid climate, stack ventilation is inefficient due to small temperature difference between the inside and outside of naturally ventilated buildings. Hence, solar induced ventilation is a feasible alternative in enhancing the stack ventilation. This paper aims to investigate the effectiveness of a proposed solar induced ventilation strategy, which combines a roof solar collector and a vertical stack, in enhancing the stack ventilation performance in the hot and humid climate. The methodology selected for the investigation is physical experimental modelling which was carried out in the actual environment. The results are presented and discussed in terms of two performance variables: air temperature and air velocity. The findings indicate that the proposed strategy is able to enhance the stack ventilation, both in semi-clear sky and overcast sky conditions. The highest air temperature difference between the air inside the stack and the ambient air (TiTo) is achieved in the semi-clear sky condition, which is about 9.9 °C (45.8 °C–35.9 °C). Meanwhile, in the overcast sky condition, the highest air temperature difference (TiTo) is 6.2 °C (39.3 °C–33.1 °C). The experimental results also indicate good agreement with the theoretical results for the glass temperature, the air temperature in the roof solar collector’s channel and the absorber temperature. The findings also show that wind has significant effect to the induced air velocity by the proposed strategy.
Keywords:Stack ventilation  Solar induced ventilation  Hot humid climate  Temperature  Air velocity
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号