首页 | 本学科首页   官方微博 | 高级检索  
     

高温风机轴承过维修与动平衡的现场处理
引用本文:吴伟. 高温风机轴承过维修与动平衡的现场处理[J]. 风机技术, 2009, 0(5): 80-82
作者姓名:吴伟
作者单位:淮北众城水泥有限责任公司,淮北市,235000
摘    要:介绍了风机轴承过维修与动平衡故障的判别误区,通过实例对故障处理的误区进行了剖析,并对风机振动原因及处理方法作了简单介绍。

关 键 词:高温风机  轴承过维修  现场动平衡

The Excessive Maintenance of Bearing and the Field Treatment of Dynamic Balance in High Temperature Fan
Wu Wei. The Excessive Maintenance of Bearing and the Field Treatment of Dynamic Balance in High Temperature Fan[J]. Compressor Blower & Fan Technology, 2009, 0(5): 80-82
Authors:Wu Wei
Abstract:This paper has introduced the judging mistake of the excessive maintenance of bearing and the fault of dynamic balance. The mistake for treating the fault is analyzed through examples. And the vibration reason and its treating method are briefly introduced.
Keywords:high temperature fan  excessive maintenance of bearing  dynamic balance on site