基金项目:国家质检总局科技计划项目(2012QK246)。
摘    要:为消除金溶液中基体的影响,配制了金基体多元素标准溶液,采用ICP-AES法对此标准溶液中Ag、Cd、Cr、Cu、Fe、Ni、Pb、Zn元素浓度进行稳定性测试,并利用线性拟合法进行数据分析。结果表明,金基体多元素标准溶液在12个月内浓度无显著性变化,证明溶液在避光和15~30℃环境下可以稳定贮存。

关 键 词:分析化恘  ICP-AES  金基体  多元素  标准溶液  稳定性
收稿时间:2015-04-13

Stability Test of the Multi-Element Standard Solution with Gold Substrate
WANG Ping,ZHANG Fengxi,LI Ting,LI Guihua and ZHU Peiming. Stability Test of the Multi-Element Standard Solution with Gold Substrate[J]. Precious Metals, 2016, 37(1): 51-55, 75. DOI: 10.3969/j.issn.1004-0676.2016.01.011
Authors:WANG Ping  ZHANG Fengxi  LI Ting  LI Guihua  ZHU Peiming
Affiliation:National Gold & Diamond Testing Center, Ji''nan 250014, China;Shandong Social Justice Institute of Metrology, Shandong Provincial Key Laboratory of Metrology and Measurement, Shandong Institute of Metrology, Ji''nan 250014, China,National Gold & Diamond Testing Center, Ji''nan 250014, China;Shandong Social Justice Institute of Metrology, Shandong Provincial Key Laboratory of Metrology and Measurement, Shandong Institute of Metrology, Ji''nan 250014, China,National Gold & Diamond Testing Center, Ji''nan 250014, China;Shandong Social Justice Institute of Metrology, Shandong Provincial Key Laboratory of Metrology and Measurement, Shandong Institute of Metrology, Ji''nan 250014, China,National Gold & Diamond Testing Center, Ji''nan 250014, China;Shandong Social Justice Institute of Metrology, Shandong Provincial Key Laboratory of Metrology and Measurement, Shandong Institute of Metrology, Ji''nan 250014, China and National Gold & Diamond Testing Center, Ji''nan 250014, China
Abstract:Standard solutions with multi-element gold substrate were prepared in order to eliminate the influence of gold substrate, ICP-AES was used to test the stability of Ag, Cd, Cr, Cu, Fe, Ni, Pb, Zn concentration, and linear fitting was applied for data analysis. The results showed that the gold substrate multi-element standard solutions were no significant change in concentration within 12 months. It proved that the solutions could be stored stably in the dark and 15~30℃ environment.
Keywords:analytical chemistry  ICP-AES  gold substrate  multi-element  standard solution  stability