连接电阻分压器的同轴电缆对测量冲击电压的影响 |
| |
引用本文: | 陈昌渔,杨学昌. 连接电阻分压器的同轴电缆对测量冲击电压的影响[J]. 高压电器, 1987, 0(5) |
| |
作者姓名: | 陈昌渔 杨学昌 |
| |
作者单位: | 清华大学(陈昌渔),清华大学(杨学昌) |
| |
摘 要: | 本文用理论分析和数值计算法的计算结果,讨论了射频同轴电缆在不同的端部匹配条件下,本身的电阻对电阻分压器的分压比和测量波形的影响。
|
Effect of Coaxial Cable Connected with Resistive Vol tage Divider on Impulse Voltage Measurements |
| |
Abstract: | The measuring errors of divider ratio and wave distortion caused by the resistance of coaxial cables in the resistor divider measuring systems are discussed.Under different terminal matchingc onditions,some useful conclusions are drawn in terms of theoretical analysis and numerical computations. |
| |