首页 | 本学科首页   官方微博 | 高级检索  
     

300 MW机组低负荷锅炉管壁超温原因分析
引用本文:芮文明,魏健鹏,牛世斌.300 MW机组低负荷锅炉管壁超温原因分析[J].发电设备,2019,33(4):285-288,292.
作者姓名:芮文明  魏健鹏  牛世斌
作者单位:国网甘肃省电力公司电力科学研究院,兰州,730070;中国铝业兰州分公司自备电厂,兰州,730070
摘    要:针对某电厂机组在低负荷运行时,锅炉过热器管发生出列变形、超温及蠕胀甚至爆管等问题,对高温过热器管进行材质分析、力学性能分析和金相显微组织分析,提出机组在低负荷和变负荷的运行调整措施及停炉期间的技术监督,调整后过热器超温及爆管现象明显好转。

关 键 词:锅炉  低负荷  过热器  蠕胀  超温  爆管

Cause Analysis of Tube Wall Overheating during Low-load Operation of a 300 MW Boiler
Rui Wenming,Wei Jianpeng,Niu Shibin.Cause Analysis of Tube Wall Overheating during Low-load Operation of a 300 MW Boiler[J].Power Equipment,2019,33(4):285-288,292.
Authors:Rui Wenming  Wei Jianpeng  Niu Shibin
Affiliation:(Electric Power Research Institute,State Grid Gansu Electric Power Company,Lanzhou 730070,China;Lanzhou Branch Self-provided Power Plantof China Aluminum Corporation,Lanzhou 730070,China)
Abstract:Rui Wenming;Wei Jianpeng;Niu Shibin(Electric Power Research Institute,State Grid Gansu Electric Power Company,Lanzhou 730070,China;Lanzhou Branch Self-provided Power Plantof China Aluminum Corporation,Lanzhou 730070,China)
Keywords:boiler  low-load operation  superheater  creep expansion  overheating  tube burst
本文献已被 维普 万方数据 等数据库收录!