首页 | 本学科首页   官方微博 | 高级检索  
     

1025t/h控制循环锅炉再热器局部超温原因分析及改进措施
引用本文:忻泉涌. 1025t/h控制循环锅炉再热器局部超温原因分析及改进措施[J]. 锅炉技术, 1997, 0(6)
作者姓名:忻泉涌
作者单位:上海锅炉厂有限公司
摘    要:本文对引进型控制循环锅炉的再热器局部超温爆管原因进行了分析探讨,并且针对已投运锅炉和新设计锅炉的不同情况,从烟气侧、蒸汽侧以及从材料等多方面途径提出切实有效的改进措施。

关 键 词:再热器汽温偏差  原因分析  改进措施

Analysis of Local Overheating in Reheater of 1025t/h Controlled Circulation Boiler and Improvement Measures
Xin Quan-yong. Analysis of Local Overheating in Reheater of 1025t/h Controlled Circulation Boiler and Improvement Measures[J]. Boiler Technology, 1997, 0(6)
Authors:Xin Quan-yong
Affiliation:Xin Quan-yong
Abstract:This paper analyzes the causes of tube failure due to overheating in relieaterof introcuced-type controlled circulation boiler and raisef effective improvement measures foroperating boilers and new design boilers with respect to the gas side, steam side and material, etc.
Keywords:Steam temperature imbalance in reheater Causes onalysis Improvement measures  
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号