首页 | 本学科首页   官方微博 | 高级检索  
     


Fiber Reinforced Polymer Composite–Wood Pile Interface Characterization by Push-Out Tests
Authors:Roberto Lopez-Anido  Antonis P. Michael  Thomas C. Sandford
Affiliation:1Associate Professor, Dept. of Civil and Environmental Engineering and Advanced Engineered Wood Composites Center, Univ. of Maine, Orono, ME?04469-5711.
2Graduate Research Assistant, Civil and Coastal Engineering Dept., Univ. of Florida, Gainesville, FL 32611-6580.
3Associate Professor, Dept. of Civil and Environmental Engineering, Univ. of Maine, Orono, ME 04469-5711.
Abstract:Structural restoration of spliced or damaged wood piles with fiber reinforced polymer (FRP) composite shells requires that shear forces be transferred between the wood core and the encasing composite shells. When a repaired wood pile is loaded, shear stresses develop between the wood pile and the FRP composite shell through the grouting material. Alternatively, shear force transfer can be developed through mechanical connectors. The objective of this study was to characterize the interfaces in wood piles repaired with FRP composite shells and grout materials. Two interfaces were studied: wood pile/grout material and a grout material/innermost FRP composite shell. A set of design parameters that control the response of both interfaces was identified: (1) extent of reduction of cross section of wood pile due to deterioration (necking); (2) type of grout material (cement-based or polyurethane); (3) use of mechanical connectors; and (4) addition of frictional coating on the innermost shell. Push-out tests by compression loading were performed to characterize the interfaces and discriminate the effect of the design parameters. The outcome of the push-out tests was evaluation of the shear stress and force versus slip response and characterization of the failure mechanism. A set of repair systems that represent different combinations of the design parameters was fabricated and the interfaces evaluated. It was found that the combination of cement-based grout and polymer concrete overlay on the innermost shell provided the most efficient shear force-slip response. A simplified piecewise linear model of shear stress versus slip at the wood/grout and grout/FRP composite interfaces with and without mechanical connectors is proposed to synthesize the experimental response.
Keywords:Piles  Wood  Fiber reinforced plastics  Composite materials  Shear  Interfaces  
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号