首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of air-flow rate and turning frequency on bio-drying of dewatered sludge
Authors:Ling Zhao  Wei-Mei Gu  Pin-Jing He  Li-Ming Shao
Affiliation:1. Institute of Thermal Engineering, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China;2. Beijing Key Laboratory of Flow and Heat Transfer of Phase Changing in Micro and Small Scale, Beijing 100044, China;3. Guodian Science and Technology Research Institute, Nanjing 210033, China;1. State Key Joint Laboratory of Environmental Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China;2. University of Chinese Academy of Sciences, Beijing 100049, China;1. GMB BioEnergie BV, P.O. Box 2, 4043 ZG Opheusden, The Netherlands;2. Delft University of Technology, Department of Biotechnology, Julianalaan 67, 2628 BC Delft, The Netherlands;3. Ghent University, Department of Biosystems Engineering, Faculty of Bioscience Engineering, Coupure links 653, B-9000 Gent, Belgium;1. School of Civil and Environmental Engineering, Ningbo University, 818 Fenghua Road, Ningbo 315211, China;2. Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China
Abstract:Sludge bio-drying is an approach for biomass energy utilization, in which sludge is dried by means of the heat generated by aerobic degradation of its organic substances. The study aimed at investigating the interactive influence of air-flow rate and turning frequency on water removal and biomass energy utilization. Results showed that a higher air-flow rate (0.0909 m3 h?1 kg?1) led to lower temperature than did the lower one (0.0455 m3 h?1 kg?1) by 17.0% and 13.7% under turning per two days and four days. With the higher air-flow rate and lower turning frequency, temperature cumulation was almost similar to that with the lower air-flow rate and higher turning frequency. The doubled air-flow rate improved the total water removal ratio by 2.86% (19.5 g kg?1 initial water) and 11.5% (75.0 g kg?1 initial water) with turning per two days and four days respectively, indicating that there was no remarkable advantage for water removal with high air-flow rate, especially with high turning frequency. The heat used for evaporation was 60.6–72.6% of the total heat consumption (34,400–45,400 kJ). The higher air-flow rate enhanced volatile solids (VS) degradation thus improving heat generation by 1.95% (800 kJ) and 8.96% (3200 kJ) with turning per two days and four days. With the higher air-flow rate, heat consumed by sensible heat of inlet air and heat utilization efficiency for evaporation was higher than the lower one. With the higher turning frequency, sensible heat of materials and heat consumed by turning was higher than lower one.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号