首页 | 本学科首页   官方微博 | 高级检索  
     


Response of Building Adjacent to Stiff Excavation Support System in Soft Clay
Authors:Richard J. Finno  L. Sebastian Bryson
Affiliation:1Professor, Dept. of Civil Engineering, Northwestern Univ., Evanston, IL?60208.
2Research Assistant, Dept. of Civil Engineering, Northwestern Univ., Evanston, IL?60208.
Abstract:A three-story school supported by shallow foundations was affected by an adjacent 12.2-m-deep excavation in soft clay in which the excavation support system was a 0.9-m-wide secant pile wall braced by both cross-lot struts and tiebacks. The school is a reinforced concrete frame structure with exterior reinforced concrete foundation walls. This paper summarizes the conditions at the site and presents correlations among construction activities, measured deformations and distortions, and attendant damage in the school. The lateral ground movements associated with the excavation were monitored with four inclinometers placed around the school. The building movements were monitored with optical survey points established on interior columns, exterior walls and on the roof, and with tiltmeters installed on the exterior foundation walls. The damage to the school mainly consisted of 300 to 500-mm-long hairline cracks in nonload bearing walls. Only a few cracks had widths greater than 6 mm. The school deformed such that the portion closest to the excavation sagged and the remainder hogged. Damage was first observed in the area of sagging when angular distortions reached 1/940 and the excavation was approximately 5.5-m deep. Angular distortions as large as 1/300 were observed at the end of the project. The data suggest that angular distortions had to be less than 1/1000 to preclude any damage to the school.
Keywords:Soft clay  Excavation  Shallow foundations  Distortion  Foundation settlement  
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号