首页 | 本学科首页   官方微博 | 高级检索  
     


Monitoring of short-lived radon progeny in mines
Authors:Skubacz K  Bywalec T
Affiliation:Central Mining Institute, Plac Gwarkow 1, 40-166 Katowice, Poland. brxks@gig.katowice.pl
Abstract:Obligatory measurements of the potential alpha energy concentration of short-lived radon progeny have been performing in the Polish underground mines since 1989. In consideration of economic aspects, an attempt was made from the very beginning to combine it with measurements of the dust concentration. Therefore the developed measuring units were an integral part of the dust samplers complying with the requirements of the State Mining Authority to apply them in underground mines. This way the developed devices could fulfil two measurement tasks simultaneously: measurement of the dust concentration and potential alpha energy concentration of short-lived radon progeny. The new device based on the thermoluminescence detectors is able to cooperate with the dust samplers made by the SKC company and equipped with a cyclone making it possible to operate them constantly for one working day. The lower limit of detection was equal about 0.04 microJ m(-3) at a 95% confidence level and 1 h pumping.
Keywords:
本文献已被 PubMed Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏