首页 | 本学科首页   官方微博 | 高级检索  
     

Dowex50W-X树脂吸附硫酸溶液中的锶
作者姓名:Meisam Hafizi  Hossein Abolghasemi  Morteza Moradi  Saeed Alamdar Milani
作者单位:1. School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran;2. Science and Technology Research Institute, Tehran, Iran
摘    要:In this study,strontium adsorption from sulfuric acid solution by different Dowex 50W-X ion exchange resins was investigated.Among these resins,Dowex 50W-X8 resin showed the maximum sorption of strontium from the aqueous solutions.The effect of pH,contact time,mass of resin,temperature,and concentration of interfering ions on strontium adsorption were evaluated to determine the optimum conditions of strontium sorption process.The kinetic models of sorption were analyzed using pseudo-first and pseudo-second order models.The results indicated that the pseudo-second order kinetic model was more appropriate than the other one.Moreover,the data obtained in this study were fitted into several sorption isotherm models and it was found that the Langmuir sorption isotherm shows the best fitting to the experimental data.

关 键 词:strontium  adsorption  ion  exchange  Dowex  50W  kinetic  model  resin  sorption  isotherm  model  
收稿时间:2010-7-9
修稿时间:2010-7-9  

Strontium adsorption from sulfuric acid solution by Dowex 50W-X resins
Meisam Hafizi,Hossein Abolghasemi,Morteza Moradi,Saeed Alamdar Milani.Strontium adsorption from sulfuric acid solution by Dowex 50W-X resins[J].Chinese Journal of Chemical Engineering,2011,19(2):267-272.
Authors:M Hafizi  H Abolghasemi  M Moradi  S Alamdar Milani
Affiliation:1. School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran;2. Science and Technology Research Institute, Tehran, Iran
Abstract:In this study, strontium adsorption from sulfuric acid solution by different Dowex 50W-X ion exchange resins was investigated. Among these resins, Dowex 50W-X8 resin showed the maximum sorption of strontium from the aqueous solutions. The effect of pH, contact time, mass of resin, temperature, and concentration of interfering ions on strontium adsorption were evaluated to determine the optimum conditions of strontium sorption process. The kinetic models of sorption were analyzed using pseudo-first and pseudo-second order models. The results indicated that the pseudo-second order kinetic model was more appropriate than the other one. Moreover, the data obtained in this study were fitted into several sorption isotherm models and it was found that the Langmuir sorption isotherm shows the best fitting to the experimental data.
Keywords:strontium adsorption  ion exchange  Dowex 50W  kinetic model  resin  sorption isotherm model
本文献已被 CNKI 等数据库收录!
点击此处可从《中国化学工程学报》浏览原始摘要信息
点击此处可从《中国化学工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号