首页 | 本学科首页   官方微博 | 高级检索  
     

非平衡气动加热条件下的材料热响应差异研究
引用本文:于明星,白书欣,徐晓亮,曹占伟. 非平衡气动加热条件下的材料热响应差异研究[J]. 材料科学与工艺, 2017, 25(6): 16-21. DOI: 10.11951/j.issn.1005-0299.20170255
作者姓名:于明星  白书欣  徐晓亮  曹占伟
作者单位:1. 国防科学技术大学 航天与材料工程学院,长沙410073;北京临近空间飞行器系统工程研究所,北京100076;2. 国防科学技术大学 航天与材料工程学院,长沙,410073;3. 北京临近空间飞行器系统工程研究所,北京,100076
基金项目:国家自然科学基金资助项目(51506008).
摘    要:针对风洞烧蚀试验中碳/碳与超高温陶瓷两种复合材料存在热响应差异的问题,本文从材料壁面催化与非平衡流场气动加热的机理出发,基于两种风洞设备设计了3个烧蚀试验状态,并对可能影响材料热响应的重要因素进行了分析.结果表明:在不同试验设备条件下,碳/碳端头驻点温度差异主要是由试验状态调试偏差和温度测量偏差造成的,而超高温陶瓷端头驻点温度的差异主要是由不同条件气流非平衡度不同、试件表面实际接受的热流不同造成;对碳/碳材料而言,由于其壁面催化特性接近完全催化壁面,在试验设备选择或状态调试时,可以不必考虑流场非平衡度的影响;而对于超高温陶瓷材料,在试验设备的选择上,则需要结合风洞非平衡流场特点,对试验考核的有效性做充分评估.相关结论可为碳/碳、超高温陶瓷复合材料防热性能的考核与评价提供参考与借鉴.

关 键 词:复合材料  碳/碳  超高温陶瓷  非平衡流场  烧蚀试验
收稿时间:2017-07-12

The difference in the thermal response under non-equilibrium aerodynamic heat
YU Mingxing,BAI Shuxin,XU Xiaoliang and CAO Zhanwei. The difference in the thermal response under non-equilibrium aerodynamic heat[J]. Materials Science and Technology, 2017, 25(6): 16-21. DOI: 10.11951/j.issn.1005-0299.20170255
Authors:YU Mingxing  BAI Shuxin  XU Xiaoliang  CAO Zhanwei
Abstract:In this paper, considering the difference of the thermal responses between C/C and ultra high temperature ceremics (UHTC) in wind tunnel ablation tests, three conditions based on two heating facilities have been designed, and the important factors influencing the thermal responses have also been analyzed from the viewpoint of materials surface catalytic and non-equilibrium flow field aerodynamic heat. The results indicated that, the difference in the stagnation temperature of C/C ends using the different testing facilities is mainly caused by the debugging deviation and temperature measurement deviation under testing conditions, whereas the difference in the stagnation temperature of UHTC ends is mainly attributed to the different in the non-equilibrium degree and the actual surface heat flow. When selecting the testing facilities, non-equilibrium degree of the flow field needs not to be considered due to the fact that C/C surface catalytic properties are close to fully catalytic one, whereas, for UHTC, the non-equilibrium flow field should be considered to fully assess the validity of the testings. The results obtained in this work can shed more insights on the assessment and evaluation of the thermal protection performance for the C/C, and UHTC composites.
Keywords:composites   C/C   UHTC   non-equilibrium flow   ablation test
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《材料科学与工艺》浏览原始摘要信息
点击此处可从《材料科学与工艺》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号