首页 | 本学科首页   官方微博 | 高级检索  
     


NMR microimaging of fluid flow in model string-type reactors
Authors:Igor V. Koptyug  Kirill V. Kovtunov  Lioubov Kiwi-Minsker
Affiliation:a International Tomography Center, 3A Institutskaya St., Novosibirsk 630090, Russia
b Laboratory of Biophysics and Wageningen NMR Centre, Wageningen University, Dreijenlaan 3, 6703 HA Wageningen, The Netherlands
c Group de Génie de la Réaction Catalytique (GGRC), SB-ISIC, Station 6, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
Abstract:Magnetic resonance microimaging (MRM) was employed to obtain quantitative velocity maps of water flowing in the channels possessing unconventional cross-section shapes formed by a bundle of parallel fibers within a tubular string-type reactor. The maps obtained demonstrate the presence of large amounts of an almost stagnant liquid in the stretched corners of the cross-sections representing distorted triangles or squares. This fact together with the irregularity of the filaments packing in the model string-type reactor was demonstrated to lead to a broad residence time distributions (RTDs) for liquid flow. Next, the pulsed field gradient NMR (PFG NMR) technique was employed to compare transport of water with that of butane gas in the same model string-type reactor. The experimentally measured average propagators (travel distance probability density functions) have demonstrated that Taylor dispersion can lead to much better RTDs for gas as compared to liquid in channels with sub-millimeter equivalent diameters. The PFG NMR data were compared with the RTD obtained using the conventional tracer time-of-flight transient response method. It is concluded that due to the differences in the quantities actually measured by the two techniques, and the significant differences in the measurement length scales (microns to 1-2 cm for NMR/MRM, tens of centimeters for transient response methods), there is no reliable way of directly comparing these results. The information obtained by NMR/MRM and more conventional techniques such as time-of-flight should be considered as complementary. In particular, NMR/MRM can reveal the reasons for the observed overall reactor performance by providing access to the transport processes on short length scales inside the reactor and by revealing structure-transport interrelations.
Keywords:Imaging   Tomography   Laminar flow   Compact string reactor   Dispersion   Residence time distribution
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号