首页 | 本学科首页   官方微博 | 高级检索  
     

某热电厂600MW锅炉水冷壁管开裂原因
引用本文:韩志远.某热电厂600MW锅炉水冷壁管开裂原因[J].理化检验(物理分册),2021(2):60-62.
作者姓名:韩志远
作者单位:内蒙古大唐国际托克托发电有限责任公司
摘    要:某热电厂600 MW锅炉水冷壁管在水压试验时出现开裂。采用宏观分析、化学成分分析、金相检验、力学性能试验等方法对开裂原因进行了分析。结果表明:水冷壁管原始管材边角部位存在夹渣缺陷,使得母材形成不连续缺陷,在水压试验升压时,裂纹扩展最终导致管子开裂失效。

关 键 词:锅炉  水冷壁管  水压试验  开裂  夹渣

Cracking Causes of Water Wall Tube of 600MW Boiler in a Thermal Power Plant
HAN Zhiyuan.Cracking Causes of Water Wall Tube of 600MW Boiler in a Thermal Power Plant[J].Physical Testing and Chemical Analysis Part A:Physical Testing,2021(2):60-62.
Authors:HAN Zhiyuan
Affiliation:(Inner Mongolia Datang International Tuoketuo Power Generation Co.,Ltd.,Hohhot 010206,China)
Abstract:The water wall tube of a 600 MW boiler in a thermal power plant cracked during the hydraulic test.The causes of cracking were analyzed by means of macro analysis,chemical composition analysis,metallographic examination and mechanical property test.The results show that there were slag inclusion defects in the corner of the original tube,which made the base metal form discontinuous defects.When the pressure was increased during the hydrostatic test,the crack propagation eventually led to the cracking failure of the tube.
Keywords:boiler  water wall tube  hydraulic test  cracking  slag inclusion