首页 | 本学科首页   官方微博 | 高级检索  
     

300MW循环流化床锅炉受热面爆管的事故处理
引用本文:尤佐元,邹苍胜,廖鹏. 300MW循环流化床锅炉受热面爆管的事故处理[J]. 锅炉制造, 2007, 0(4): 19-21
作者姓名:尤佐元  邹苍胜  廖鹏
作者单位:云南大唐国际红河发电有限责任公司,云南省,开远市,661600
摘    要:简要介绍300MW循环流化床锅炉受热面布置情况、受热面爆管的现象和处理情况以及预防措施。

关 键 词:300MW循环流化床锅炉  爆管  事故处理  预防措施
文章编号:CN23-1249(2007)04-0019-03
修稿时间:2007-02-24

Treatment of Heating Surface Tube Rupture Accident on a 300MW CFB Boiler
You Zuoyuan,Zou Cangsheng,Liao Peng. Treatment of Heating Surface Tube Rupture Accident on a 300MW CFB Boiler[J]. Boiler Manufacturing, 2007, 0(4): 19-21
Authors:You Zuoyuan  Zou Cangsheng  Liao Peng
Affiliation:Yunnan Datang Interna Tional Honghe Power Generationa Co. Ltd. , Kaiyuan 661600, China
Abstract:The heating surface of a 300MW CFB boiler is introduced briefly in this paper.The paper analyses the heating surface tube rupture accident and develops the treatment procedure and precautionary measures for tube rupture.
Keywords:300MW CFB boiler  tube rupture  accident treatment  precautionary measures
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏