首页 | 本学科首页   官方微博 | 高级检索  
     

卷烟机剔除梗签物中含丝量的检测
引用本文:曾静,李斌,冯志斌,孔臻,江威,刘栋,解晓翠.卷烟机剔除梗签物中含丝量的检测[J].烟草科技,2012(8):5-7,11.
作者姓名:曾静  李斌  冯志斌  孔臻  江威  刘栋  解晓翠
作者单位:1. 广东中烟工业有限责任公司技术中心,广州市荔湾区中山七路333号,510145
2. 中国烟草总公司郑州烟草研究院烟草行业烟草工艺重点实验室,郑州高新技术产业开发区枫杨街2号,450001
3. 广东中烟工业有限责任公司技术中心,广州市荔湾区中山七路333号 510145;中国烟草总公司郑州烟草研究院烟草行业烟草工艺重点实验室,郑州高新技术产业开发区枫杨街2号 450001
基金项目:2009年烟草行业标准项目“卷烟机剔除梗签物中含丝量的测定”
摘    要:为了有效控制卷烟机剔除梗签物中烟丝含量,利用两级流态化理论分离梗签与烟丝,在考察梗丝与烟丝的基本流化特性的基础上,确定了两级流态化的流速条件,建立了检测卷烟机剔除梗签物中含丝量的方法。考察了被测样品质量相同含丝量不同及梗签物含丝量相同质量不同时对检测结果的影响。结果表明:①当被测样品质量不变,在理论含丝量为0.5%~5.5%时,检测结果的标准偏差随含丝量水平的增加没有明显变化,相对误差随含丝量水平的增加有降低的趋势,即正确度有所提高;②当梗签物含丝量不变,被测样品质量为100~500 g时,检测结果的标准偏差随着质量水平的降低,略有降低;相对误差在质量为200~300 g内较小。

关 键 词:卷烟机剔除梗签物  含丝量  临界流化速度  悬浮速度

Determination of Tobacco Shred Content in Rejects from Cigarette Maker
ZENG Jing , LI Bin , FENG Zhibin , KONG Zhen , JIANG Wei , LIU Dong , XIE Xiaocui.Determination of Tobacco Shred Content in Rejects from Cigarette Maker[J].Tobacco Science & Technology,2012(8):5-7,11.
Authors:ZENG Jing  LI Bin  FENG Zhibin  KONG Zhen  JIANG Wei  LIU Dong  XIE Xiaocui
Affiliation:1.Technology Center of China Tobacco Guangdong Industrial Co.,Ltd.,Guangzhou 510145,China 2.Key Laboratory of Tobacco Processing Technology of CNTC,Zhengzhou Tobacco Research Institute of CNTC,Zhengzhou 450001,China
Abstract:In order to control the tobacco shred content in rejects from cigarette maker effectively,on the basis of investigating the basic fluidization characters of cut stem and cut tobacco,a method for determining the tobacco shred content in the rejects by a two-stage winnower was developed,and the preferable air velocities in the two-stage winnower were determined.The samples of different conditions were studied,the results showed that:1) for samples of the same mass,when tobacco shred content ranged from 0.5% to 5.5%,the relative error of test results decreased with the increase of tobacco shred content,though the standard deviation did not change obviously;2) for samples of the same tobacco shred content,when the mass of sample ranged from 100 to 500 g,the standard deviation of test results decreased slightly with the decrease of mass,and the relative error was smaller at the mass range of 200-300 g.
Keywords:Rejects from cigarette maker  Tobacco shred content  Critical fluidizing velocity  Floating velocity
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏