Detailed Comparison of Injection-Seeded and Self-Seeded Performance of a 1060-nm Gain-Switched Fabry–PÉrot Laser Diode |
| |
Authors: | Vu K.T. Malinowski A. Roelens M.A.F. Richardson D.J. |
| |
Affiliation: | Optoelectron. Res. Centre, Univ. of Southampton, Canberra, ACT; |
| |
Abstract: | We investigate and compare the performance of a gain-switched picosecond Fabry-Perot laser diode operated at 1.06 mum under both injection- and self-seeded conditions. Our experiments show that comparable performance can be obtained for both modes of operation, with the self-seeding arrangement offering overall benefits in terms of reduced system complexity and cost, providing the associated quantization of available pulse repetition rate can be tolerated. |
| |
Keywords: | |
|
|