摘    要:以北京某污水处理厂工程项目为例,从电机的选择、变压器的选择、配电设备的选择、母线及电缆的选择、变频器的选择几个方面,对660V配电电压在污水处理厂中等功率变频调速设备上的应用进行分析。

关 键 词:660V电压等级  污水处理厂  变频调速  中等功率水泵电机  应用分析

Application Analysis of 660V Frequency Control Equipment in Sewage Treatment Plant
YAO Rui.Application Analysis of 660V Frequency Control Equipment in Sewage Treatment Plant[J].Building Electricity,2012,31(10):37-40.
Authors:YAO Rui
Affiliation:YAO Rui (Beijing General Municipal Engineering Design & Research Institute, Beijing 100082, China)
Abstract:Based on project case, the application of 660V distribution voltage to the medium-power frequency control equipment in a in Beijing is analyzed in terms transformer, power distribution cables and frequency converter sewage treatment plant of selection of motor, equipment, busbar,
Keywords:660 V voltage class Sewage treatmentplant Frequency control Medium-power pump motorApplication analysis