摘    要:对太钢降压变电站烧毁限流电抗器事故原因进行了技术理论分析,采取改进电抗器与断路器接线方式的措施,消除了系统隐患。

关 键 词:过电压  电抗器  烧毁  电感线圈  接地  短路
文章编号:1006-6764(2007)01-0012-03
收稿时间:2006-06-26
修稿时间:2006-06-26

Burned Causes Analysis of Reactor in Step-down Substation and Improving Measures
CHEN Ren-jie,WEN Zhi-hong. Burned Causes Analysis of Reactor in Step-down Substation and Improving Measures[J]. Metallurgical Power, 2007, 0(1): 12-14
Authors:CHEN Ren-jie  WEN Zhi-hong
Abstract:Burned causes of current-limiting reactor for the step-down substation of Taiyuan Iron & Steel(Group) Co.,Ltd.were analyzed technologically and theoretically.The wiring modes of reactor and disconnector were improved,which eliminated hidden troubles of the electric system.
Keywords:over voltage  reactor  burning  inductance coil  grounding  short circuit  