首页 | 本学科首页   官方微博 | 高级检索  
     

300 MW循环流化床锅炉SNCR运行优化
引用本文:张古雪. 300 MW循环流化床锅炉SNCR运行优化[J]. 山西能源与节能, 2014, 0(9): 161-162
作者姓名:张古雪
作者单位:神华神东电力有限责任公司新疆米东热电厂;
摘    要:按照新的环保排放要求,2014年7月开始,特别区域的NOx排放要控制在100 mg/m3,为了能够达标排放,米东热电厂于2013年进行了脱硝系统改造,在系统投运后一直存在尿素用量偏大,通过运行优化调整,脱硝还原剂用量大大降低。在保证满足环保指标排放的同时,也大大降低了脱硝成本。

关 键 词:300  MW  锅炉  SNCR  优化

SNCR Operation Optimization of 300 MW Circulating Fluidized Bed Boilers
ZHANG Gu-xue. SNCR Operation Optimization of 300 MW Circulating Fluidized Bed Boilers[J]. Shanxi Energy and Conservation, 2014, 0(9): 161-162
Authors:ZHANG Gu-xue
Affiliation:ZHANG Gu-xue (Xinjiang Midong Thermal Power Plant of Shenhua Shendong Electric Power Co., Ltd., Urumqi 830000, Xinjiang, China)
Abstract:In accordance with new emission requirements for environmental protection, the emission of NOxin special areas will be controlled to 100 mg/m3 starting from July 2014. In order to be able to discharge up to the standard, Midong thermal power plant reformed the denitration system in 2013. Since the system was put into operation, relatively large amount of urea had been used. The amount of denitrification reducing agent has been greatly reduced by the optimal adjustment of operation, which not only ensures that the emissions can meet the environmental targets, but also greatly reduces the cost of denitrification.
Keywords:300 MW  boiler  SNCR  optimization
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号