首页 | 本学科首页   官方微博 | 高级检索  
     

高压洗涤器工艺气不冷凝故障分析及对策
引用本文:贾春临,徐发淮,韩建军.高压洗涤器工艺气不冷凝故障分析及对策[J].石油化工应用,2009,28(7):88-89,101.
作者姓名:贾春临  徐发淮  韩建军
作者单位:中国石油宁夏石化公司,宁夏银川,750026
摘    要:介绍了高压洗涤器中工艺气不冷凝现象,分析了故障产生的原因及处理对策,为尿素装置处理类似问题提供了借鉴。

关 键 词:高压洗涤器  工艺气  冷凝  措施

Reasons for failure of the technologic gas not condensating and countermeasure in high pressure scrubber
JIA Chunlin,XU Fahuai,HAN Jianjun.Reasons for failure of the technologic gas not condensating and countermeasure in high pressure scrubber[J].Petrochemical Industry Application,2009,28(7):88-89,101.
Authors:JIA Chunlin  XU Fahuai  HAN Jianjun
Abstract:Presents the phenomenon technologic gas not condensating in high pressure scrubber,analyzes the reasons of failures and proposes corresponding countermeasures, provides valuable experience for settling similar probelms in urea unit.
Keywords:high pressure scrubber  technologic gas  condensate  countermeasure
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号