首页 | 本学科首页   官方微博 | 高级检索  
     

DG410t/h循环流化床锅炉调试研究与分析
引用本文:马登卿,杨守伟,刘亚军,李士军.DG410t/h循环流化床锅炉调试研究与分析[J].水利电力机械,2008,30(2):46-49,69.
作者姓名:马登卿  杨守伟  刘亚军  李士军
作者单位:河北省电力研究院,河北石家庄050021
摘    要:以河北热电有限责任公司技改工程4台CFB锅炉为例,对CFB锅炉调试过程中遇到的锅炉烘烤、冷态动力场试验、锅炉试投煤等关键技术进行了研究和分析,提出了CFB锅炉运行的几点建议。

关 键 词:CFB  锅炉  调试
文章编号:1674-1951(2008)02-0046-04
收稿时间:2007-12-20
修稿时间:2007年12月20

Research and analysis on DG410 t/h CFB commissioning
MA Deng-qing, YANG Shou-wei, LIU Ya-jun, LI Shi-jun.Research and analysis on DG410 t/h CFB commissioning[J].Water Conservancy & Electric Power Machinery,2008,30(2):46-49,69.
Authors:MA Deng-qing  YANG Shou-wei  LIU Ya-jun  LI Shi-jun
Abstract:In view of four sets of CFB boiler in the Hebei Cogeneration technological transformation project, the key technology such as toaster, cold dynamical field trial, adding coal test, and some problems occurred in the boiler commissioning were researched and analyzed. Some advice for CFB running was given.
Keywords:CFB  boiler  commissioning
本文献已被 维普 等数据库收录!