断路器偷跳引起的重合闸反复动作
引用本文:郭又华,赵俊,朱雨.断路器偷跳引起的重合闸反复动作[J].四川电力技术,2011,34(6):32-35.
作者姓名:郭又华  赵俊  朱雨
作者单位:1. 四川省电力公司超(特)高压运行检修公司,四川成都,610041
2. 成都电业局继电保护所,四川成都,610021
摘    要:断路器偷跳可能造成严重后果,应予以重视。介绍一起500kV断路器偷跳引起的重合闸反复动作案例,提出了某些情况下偷跳会引起重合闸反复动作、造成断路器周期性跳合类似“跳跃”的现象,详细分析了该现象产生原因及过程,最后提出了能避免重合闸反复动作,加快断路器三相跳闸的解决方案。

关 键 词:断路器  偷跳  重合闸

Repeating Reclosing Caused by Non-fault Trip of Circuit Breaker
Guo Youhua Zhao Jun Zhu Yu.Repeating Reclosing Caused by Non-fault Trip of Circuit Breaker[J].Sichuan Electric Power Technology,2011,34(6):32-35.
Authors:Guo Youhua Zhao Jun Zhu Yu
Affiliation:Guo Youhua Zhao Jun Zhu Yu
Abstract:The non-fault trip of circuit breaker may cause serious consequences,so it should be much accounted.A case of repeating reclosing caused by non-fault trip of a 500 kV circuit breaker is introduced.The phenomenon,such as repeating reclosing and periodically tripping and closing of circuit breaker like jumping,are put forward in some cases,which are caused by non-fault trip.The occurring reasons and process of this phenomenon are analyzed in detail.Finally,the solutions are proposed to avoid repeating reclosi...