首页 | 本学科首页   官方微博 | 高级检索  
     

600MW超临界机组燃烧调整中SOFA摆角的作用
引用本文:周立群,张碧珠. 600MW超临界机组燃烧调整中SOFA摆角的作用[J]. 水利电力机械, 2010, 0(4): 8-11
作者姓名:周立群  张碧珠
作者单位:福建华电可门发电有限公司;
摘    要:通过锅炉燃烧调整试验,标定了二次风量、O2含量和排烟温度,进行了SOFA摆角调整对汽温偏差影响的试验,给出了SOFA风水平摆角优化运行的推荐参数。

关 键 词:超临界锅炉  燃烧调整  汽温偏差  SOFA摆角  优化

Effect of SOFA swing angle in combustion adjustment of 600MW supercritical unit
ZHOU Li-qun,ZHANG Bi-zhu. Effect of SOFA swing angle in combustion adjustment of 600MW supercritical unit[J]. Water Conservancy & Electric Power Machinery, 2010, 0(4): 8-11
Authors:ZHOU Li-qun  ZHANG Bi-zhu
Affiliation:ZHOU Li-qun,ZHANG Bi-zhu(Fujian Huadian Kemen Power Generation Corporation Limited,Fuzhou 350512,China)
Abstract:Based on the boiler combustion adjustment experiment,the second air flow,the O2 content and the flue gas temperature were calibrated and verified.The influence of the SOFA swing angle adjustment on the steam temperature deviation was tested,and the optimized operation parameters of horizontal swing angle of SOFA were recommended.
Keywords:supercritical boiler  combustion adjustment  steam temperature deviation  swing angle of separated over-fired air(SOFA)  optimization  