A study on an online measurement method to determine the oil discharge ratio by utilizing Coriolis mass flow meter in a calorimeter
Affiliation:1. Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil;2. Department of Mechanical Engineering, Francisco de Paula Santander University, Ocaña, Colombia;3. Post-graduate Program in Mechanical and Materials Engineering (PPGEM), Federal Technological University of Paraná (UTFPR), Curitiba, PR, Brazil
Abstract:In this paper, an online measurement method of oil discharge ratio (ODR) is experimentally investigated based on a compressor calorimeter with the Coriolis mass flowmeter (CMF). In this method, the oil concentration is determined by a linear mixing law of the specific volume model using the density of the refrigerant, oil and refrigerant-oil mixture obtained by CMF. During the testing, the light absorption method is also conducted simultaneously for the comparison. The results indicate that the presented CMF based density method has an average relative deviation of 4.28%. The accuracy of the CMF based density method is superior to the light absorption method, which has the relative deviation of −8∼23% compared with the standard sampling method. The presented CMF-based method can be expected to be used for future ODR measurement due to its non-sampling, online, and accurate features.
Keywords:Online measurement  Oil discharge ratio  Coriolis mass flowmeter  Compressor calorimeter  Mesure en ligne  Taux d'huile au refoulement  Débitmètre de Coriolis  Calorimètre du compresseur