首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental investigation of built-up cold-formed steel section battened columns
Affiliation:1. Department of Civil Engineering, Johns Hopkins University, Baltimore, MD, USA;2. School of Civil Engineering, University of Tehran, Tehran, Iran;3. Department of Mathematics and Computer Science, West Virginia State University, USA;4. School of Civil Engineering, University of Sydney, Sydney, Australia;1. Department of Civil and Environmental Engineering, The University of Auckland, New Zealand;2. School of Engineering and Science, Curtin University Sarawak, Miri, Sarawak, Malaysia;1. Department of Civil and Environmental Engineering, The University of Auckland, New Zealand;2. School of Engineering and Science, Curtin University Sarawak, Miri, Sarawak, Malaysia;3. Swinburne University of Technology, Sarawak Campus, Kuching, Sarawak, Malaysia
Abstract:This paper presents an experimental investigation on behaviour and design of built-up cold-formed steel section battened columns. The built-up columns were pin-ended and consisted of two cold-formed steel channels placed back-to-back at varied spacing of intersection. The two channels were connected using batten plates, with varying longitudinal spacing. The cold-formed steel channel sections were manufactured by brake-pressing flat strips having a plate thickness of 2 mm. The built-up cold-formed steel section battened columns had different slenderness and geometries but had the same nominal length of 2200 mm. The column strengths, load–axial shortening, load–lateral displacement and load–axial strain relationships were measured in the tests. In addition, the failure modes and deformed shapes at failure were observed in the tests and reported in this paper. Overall, the built-up column tests provided valuable experimental data regarding the column behaviour that compensated the lack of information on this form of construction as well as used to develop nonlinear 3-D finite element models. The column strengths measured experimentally were compared against design strengths calculated using the North American Specification, Australian/New Zealand Standard and European Code for cold-formed steel columns. Generally, it is shown that the specifications were unconservative for the built-up cold-formed steel section battened columns failing mainly by local buckling, while the specifications were conservative for the built-up columns failing mainly by elastic flexural buckling.
Keywords:Built-up columns  Cold-formed steel  Experimental investigation  Stability  Steel structures design
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号