首页 | 本学科首页   官方微博 | 高级检索  
     

循环水凉水塔风扇紧固螺栓断裂原因分析
引用本文:庄锁良,李江. 循环水凉水塔风扇紧固螺栓断裂原因分析[J]. 石油化工腐蚀与防护, 2002, 19(5): 33-34
作者姓名:庄锁良  李江
作者单位:北京燕化公司炼油厂设备处,北京,102503
摘    要:燕化凉水塔鼓风扇 18- 8不锈钢材质的U型螺栓在服役 16 0小时后发生断裂。经检测 ,其化学成分、金相组织、力学性能未见异常。分析认为 ,螺栓断裂是由于交变载荷作用下的疲劳破坏所致 ,经改用 2Cr13材质后运行正常

关 键 词:螺栓  不锈钢  疲劳破坏  2Cr13
修稿时间:2001-12-26

Fracture Analysis of Tightening Bolts in Cooling Tower Fans
Zhuang Suoliang,Li Jiang. Fracture Analysis of Tightening Bolts in Cooling Tower Fans[J]. Petrochemical Corrosion and Protection, 2002, 19(5): 33-34
Authors:Zhuang Suoliang  Li Jiang
Abstract:U-type 18-8 bolts in the cooling tower fans in the refinery of Yanshan Petrochemical Company fractured after only 160 hours' service. The testing found nothing wrong in the chemical compositions, metallographic structure and mechanic performance. The analysis concluded that the fracture was caused by the fatigue failure under the alternating loads. The operation became normal after the bolts were replaced with 2Cr13 metallurgy.
Keywords:bolt   stainless steel   fatigue fracture   2Cr13