Optimal siting and sizing of UPFC using evolutionary algorithms
Affiliation:1. Department of Electrical and Electronics Engineering, Loyola-ICAM College of Engineering and Technology, Tamil Nadu, India;2. Department of Electrical and Electronics Engineering, Thiagarajar College of Engineering, Tamil Nadu, India;3. Department of Electrical and Electronics Engineering, Kamaraj College of Engineering and Technology, Tamil Nadu, India;1. Department of Electrical Engineering, University Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia;2. Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Fars, Iran;1. Department of Electrical and Electronics Engineering, Faculty of Engineering, Avinasilingam University, Coimbatore 641108, India;2. Department of Electrical and Electronics Engineering, Coimbatore Institute of Technology, Coimbatore 641014, India;3. Department of Instrumentation and Control Engineering, P.S.G. College of Technology, Coimbatore 641004, India;1. Department of Technical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran;2. Centre of Excellence for Power System Automation and Operation, Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
Abstract:This paper addresses an application of evolutionary algorithms to optimal siting and sizing of UPFC which are formulated as single and multiobjective optimization problems. The decision variables such as optimal location, both line and distance of UPFC from the sending end, control parameters of UPFC and system reactive power reserves are considered in the optimization process. Minimization of total costs including installation cost of UPFC and enhancement of the loadability limit are considered as objectives. To reduce the complexity in modeling and the number of variables and constraints, transformer model of UPFC is used for simulation purposes. CMAES and NSGA-II algorithms are used for optimal siting and sizing of UPFC on IEEE 14 and 30 bus test systems. NSGA-II algorithm is tested on IEEE 118 bus system to prove the versatility of the algorithm when applied to large systems. To validate the results of transformer model of UPFC for optimal siting and sizing, results using other models are considered. In single objective optimization problem, CMAES algorithm with transformer model yields better results when compared to other UPFC models. The statistical results conducted on 20 independent trials of CMAES algorithm authenticate the results obtained. For validating the results of NSGA-II with transformer model for optimal siting and sizing of UPFC, the reference Pareto front generated using multiple run CMAES algorithm by minimizing weighted objective is considered. In multiobjective optimization problem, the similarity between the generated Pareto front and the reference Pareto front validates the results obtained.
Keywords:Optimal location  Transformer model of UPFC  Evolutionary algorithms  PDIP  Sensitivity analysis  Maximum loadability
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号