首页 | 本学科首页   官方微博 | 高级检索  
     

湿法烟气脱硫系统氧化风机断轴原因分析
引用本文:张桂平.湿法烟气脱硫系统氧化风机断轴原因分析[J].电力技术,2010(5).
作者姓名:张桂平
作者单位:广东珠海金湾发电有限公司
摘    要:金湾发电厂#4机组湿法烟气脱硫系统配置了两台氧化风机,投入运行两年后,#4-1氧化风机从动轴断裂。本文详细介绍了风机断轴前后的具体情况,并对断轴原因进行了深入分析。分析表明,#4-1氧化风机断轴的原因是轴的使用材料不符合要求;滤网碎片掉入缸体,风机间隙突变;风机运行负荷大,运行温度高。

关 键 词:湿法烟气脱硫  氧化风机  断轴  滤网  间隙

Reason Analysis of Shaft Breakage of Oxidation Fan in the Wet FGD System
Authors:ZHANG Gui-ping
Abstract:Two oxidation fans for the wet flue gas desulphurization(FGD) system were equipped in the No.4 unit of Jinwan power plant.After two years operation,the driven shaft of #4-1 oxidation fan broke.The concrete situations of the fan before and after breakage were described in detail,and the reason of the breakage was analyzed in depth.The result showed that the breakage reasons of #4-1 oxidation fan were as below: the materials didn’t meet the requirements;the chip of the filter screen fell down into cylinder an...
Keywords:wet FGD  oxidation fan  shaft breakage  filter screen  gap