首页 | 本学科首页   官方微博 | 高级检索  
     

Z型接地变压器在谐振接地系统中的运用
引用本文:黄焕鹏. Z型接地变压器在谐振接地系统中的运用[J]. 广东输电与变电技术, 2007, 0(6): 21-24
作者姓名:黄焕鹏
作者单位:广东电网公司潮州供电局
摘    要:介绍了谐振接地系统中Z型接地变压器的接线及原理、结构与特点和Z型接地变压器的直流电阻、电压比、零序阻抗、空载、负载等项目的试验方法。提供了现场试验的有关数据和经验,分析了现场试验中应注意的问题和解决的方法。

关 键 词:Z型接地变压器  谐振接地  零序阻抗

Application of Zigzag Grounding Transformer in Neutral Grounding Power System with Resonance
Huang Huanpeng. Application of Zigzag Grounding Transformer in Neutral Grounding Power System with Resonance[J]. Guangdong Power Transmission Technology, 2007, 0(6): 21-24
Authors:Huang Huanpeng
Affiliation:Guangdong Power Grid Corporation Chaozhou Power Supply Bureau Huang Huanpeng
Abstract:This paper introduces principle,structure and characters of zigzag grounding transformer used in neutral grounding power system with resonance,the test method is also presented.Based on the operating data and experience,the problems,happened in site is analyzed,and solution way is introduced.
Keywords:Zigzag grounding transformer  Resonance grounding  Zero-sequence impedance
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号