基于Modbus-RTU通讯协议的组态王与TOP9500通讯
引用本文:胡雄峰,郑应霞. 基于Modbus-RTU通讯协议的组态王与TOP9500通讯[J]. 工业控制计算机, 2010, 23(3): 9-10
作者姓名:胡雄峰  郑应霞
作者单位:华东勘测设计研究院,浙江,杭州,310014;华东勘测设计研究院,浙江,杭州,310014
摘    要:介绍了组态王6.5与TOP9500通讯的问题。由于组态王自身支持基于Modbus-RTU通讯协议的TOP9500智能电力测量仪通讯,使通讯方法变得简单,并以浙江某电厂的现地控制单元公共站为例,给出了工程实际应用中碰到的问题及解决方案。

关 键 词:组态王  ModbusRTU  TOP9500  通讯

Communication Between KingView and TOP9500 Based on Modbus-RTU
Hu Xiongfeng et al. Communication Between KingView and TOP9500 Based on Modbus-RTU[J]. Industrial Control Computer, 2010, 23(3): 9-10
Authors:Hu Xiongfeng et al
Abstract:In this paper,communication between the KingView6.5 and TOP9500 is described in detail.It makes the communication much easier with the help of the TOP9500 communication based upon the Modbus-RTU communication protocol which is supported by kingview itself.As you can see from the example of the LCU of a plant in Zhejiang,it gives out the problems which have been faced in the practice and the solution method.
Keywords:KingView 6.5  Modbus-RTU  TOP9500  communication  
本文献已被 CNKI 维普 万方数据 等数据库收录!