两种调速型高压水除鳞泵站的节能分析与比较
引用本文:罗廷鉴,陈烨.两种调速型高压水除鳞泵站的节能分析与比较[J].节能,2010,29(4):36-40.
作者姓名:罗廷鉴  陈烨
作者单位:韶关钢铁集团有限公司,钢轧工程指挥部,广东,韶关512123
摘    要:通过计算泵站的待机/打压节能率和传动效率,绘制泵站在不同打压比时的能耗曲线,对液力耦合器调速和变频调速两种高压水除鳞泵站进行节能效果分析和比较,找到了影响调速节能效果的因素。

关 键 词:高压水除鳞  离心泵  节能  变频  耦合器

Energy-saving analysis and comparision on two types of speed-regulation pump stations for high-pressure descaling systems
LUO Ting-jian,CHEN Ye.Energy-saving analysis and comparision on two types of speed-regulation pump stations for high-pressure descaling systems[J].Energy Conservation,2010,29(4):36-40.
Authors:LUO Ting-jian  CHEN Ye
Abstract:By calculating the waiting/working energy-saving ratio and the transmission efficiency of the pump stations,and making the graph of energy consumption of the pump stations at different waiting/working time ratios,this article analyzed and compared the energy-saving effects between Fluid Coupling and Transducer speed-regulation pump stations for High-pressure Descaling Systems,and found the factors which affect the energy-saving effect.
Keywords:high-pressure descaling  centrifugal pump  energy-saving  transducer  fluid coupling