脱盐水泵与循环水泵改造总结
引用本文:翟玉龙,张礼波. 脱盐水泵与循环水泵改造总结[J]. 大氮肥, 2009, 32(6): 396-398
作者姓名:翟玉龙  张礼波
作者单位:中国石油化工股份有限公司湖北化肥分公司,湖北枝江,443200
摘    要:分析脱盐水泵与循环水泵存在问题和经常跳车的原因,通过对实际运行工况与设计工况进行分析与计算,认为切割水泵叶轮,减小叶轮直径,可以节能降耗,稳定生产,实施后效果良好。

关 键 词:脱盐水泵  叶轮切割  节能

A SUMMARY OF BOILER DM-WATER PUMP RE-CONSTRUCTION
Zai Yulong,Zhang Libo. A SUMMARY OF BOILER DM-WATER PUMP RE-CONSTRUCTION[J]. Large Scale Nitrogenous Fertilizer Industry, 2009, 32(6): 396-398
Authors:Zai Yulong  Zhang Libo
Affiliation:( SINOPEC Hubei Chemical Fertilizer Branch, Zhijiang, 443200)
Abstract:The problems in DM-water pump for coal-fired boiler and cause for frequent trip-up are analyzed; when there is a big deviation in actual coal-fired boiler DM-water pump running condition from design condition, by means of analysis and calculation to the system it takes that cutting the water-pump impeller isone of simple measures to reduce the energy consumption and raise water quantity under a stabilize operating condition.
Keywords:coal-fired boiler DM-water pump   impeller-cutting   energy-saving