首页 | 本学科首页   官方微博 | 高级检索  
     


Kinematic calibration of precise 6-DOF stewart platform-type positioning systems for radio telescope applications
Authors:Juan Carlos JáUREGUI  Eusebio E HERNáNDEZ  Marco CECCARELLI  Carlos LóPEZ-CAJúN  Alejandro GARCíA
Affiliation:1. División de Estudios de Posgrado, Facultad de Ingeniería, Universidad Autónoma de Quéretaro Quéretaro, Qro. Mexico; 2. National Polytechnic Institute, IPN, Section of Graduate Studies and Research, ESIME-UPT, México D.F., Mexico; 3. Laboratory of Robotics and Mechatronics University of Cassino, Italy; 4. Universidad Autónoma de Quéretaro Querétaro, Qro. México; 5. CIATEQ, A.C. Aguascalientes, Ags. México
Abstract:The pose accuracy of a parallel robot is a function of the mobile platform posture. Thus, there is no a single value of the robot’s accuracy. In this paper, two novel methods for estimating the accuracy of parallel robots are presented. In the first method, the pose accuracy estimation is calculated by considering the propagation of each error, i.e., error variations are considered as a function of the actuator’s stroke. In the second method, it is considered that each actuator has a constant error at any stroke. Both methods can predict pose accuracy of precise robots at design stages, and/or can reduce calibration time of existing robots. An example of a six degree-of-freedom parallel manipulator is included to show the application of the proposed methods.
Keywords:pose errors  error estimation  parallel robot  radio telescopes  
点击此处可从《》浏览原始摘要信息
点击此处可从《》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号