Long-term measurements of radon equilibrium factor in Greek dwellings |
| |
Authors: | Clouvas A Xanthos S Antonopoulos-Domis M |
| |
Affiliation: | Nuclear Technology Laboratory, Department of Electrical and Computer Engineering, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece. clouvas@eng.auth.gr |
| |
Abstract: | The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During October 1999-May 2000 the radon equilibrium factor was measured in 25 apartments randomly distributed in Thessaloniki. The mean value of the equilibrium factor F is 0.47 +/- 0.09, close to the typical value of 0.4 adopted by UNSCEAR. |
| |