b Europe Technology Development at IMEC, Applied Materials Europe, Leuven, Belgium
c Copper PVD Integration Systems and Modules, Applied Materials, Santa Clara, CA 95054, USA
Abstract:
Passivated single damascene copper SiO2 damascene lines were evaluated in combination with TiSiN and Ta(N)/Ta diffusion barriers. Leakage current, breakdown and time-dependent dielectric breakdown properties were investigated on a wafer level basis for temperatures ranging between room temperature and 150 °C. It is found that the leakage performance of the wafers with a TiSiN barrier is better at room temperature, but at 150 °C the performance levels out with Ta(N)/Ta. Time-dependent dielectric breakdown measurements at 150 °C show that the lifetime of the interconnect is higher with the selected Ta(N)/Ta barrier than for TiSiN.