摘    要:针对大型低频换能器指向性难以测量的问题,提出了一种基于四元十字阵的测量方法以获取大型低频换能器的指向性。利用到达四元十字阵阵元的时延差信息,结合双曲面交汇法对换能器进行定位,并根据四元十字阵阵元测得的声信号实现大型低频换能器指向性的测量;对定位算法进行理论仿真,设计并进行了湖上试验以测量模拟声源的指向性;对湖上试验测量数据进行计算分析,并与模拟声源在消声水池中的测量结果进行比较,两者-3 dB波束开角的测量结果相差在10%以内。此方法可以用于低频换能器指向性的测量。

关 键 词:低频换能器  指向性  四元十字阵  双曲面交汇法  时延差
收稿时间:2018/8/15 0:00:00
修稿时间:2018/10/19 0:00:00

A method of directivity measurement based on four-element cross array
GUO Shi-xu,ZHU Meng-qi,WANG Xiao-bo,WANG Yue-bing,ZHAO Peng and YANG Min.A method of directivity measurement based on four-element cross array[J].Technical Acoustics,2019,38(4):464-469.
Authors:GUO Shi-xu  ZHU Meng-qi  WANG Xiao-bo  WANG Yue-bing  ZHAO Peng and YANG Min
Affiliation:China Jiliang University, Hangzhou 318000, Zhejiang, China,China Jiliang University, Hangzhou 318000, Zhejiang, China,Zhejiang Province Institute of Metrology, Hangzhou 310018, Zhejiang, China,China Jiliang University, Hangzhou 318000, Zhejiang, China,China Jiliang University, Hangzhou 318000, Zhejiang, China and Harbin Engineering University, Harbin 150001, Heilongjiang, China
Abstract:Aiming at the problem that the directivity of large low frequency transducer is difficult to measure, a measurement method based on four-element cross array is proposed in this paper. By measuring the time delay differences between the four-elements of the cross array and combining with the hyperboloid intersection method to locate the transducer, the measurement of the directivity of large low frequency transducer can be realized by measuring the acoustic signals received by the four-elements of the cross array. The transducer locating algorithm is simulated according to the measurement method, and the corresponding lake experiment is designed for measuring the directivity of the simulated sound source based on this method. The measurement results are analyzed and compared with the results of the laboratory measurement method in anechoic tank. It is shown that the difference between both measurement results of -3dB beam width is within 10%, and so this method can be used for testing the directivity of large low frequency transducer in modern sonar equipment.
Keywords:low frequency transducer  directivity  four-element cross array  hyperboloid convergence method  time delay
本文献已被 CNKI 等数据库收录!
点击此处可从《声学技术》浏览原始摘要信息
点击此处可从《声学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号