Abstract: | Small-model tests were performed to examine the integrity of the containment flange gasket in a severe accident. During a severe accident, containment structures suffer slow pressurization at relatively high temperatures. A realistic understanding of containment performance in such conditions is a major concern in developing an accident management strategy. This paper describes the results of experiments on the sealing capability of flange gaskets at high pressures and high temperatures. Silicone-rubber gaskets, which are used as the sealing material in BWR plant primary containment vessels (PCV) in Japan, were examined in small-model tests. The gaskets show sufficient sealing capability up to 225°C at 20 kgf/cm2. When applying the leakage characteristics specified in this paper to codes for severe accidents, the results should be examined carefully based on realistic heattransfer phenomena. |