首页 | 本学科首页   官方微博 | 高级检索  
     


Measuring method for flow rate distribution between cells in a polymer electrolyte fuel cell stack
Authors:Fumiaki Sekine  Mika Eguchi  Yasuyuki Tsutsumi
Affiliation:a Major in Materials and Molecular Science, Ibaraki University, Sciences and Engineering Material, 4-12-1, Nakanarusawa, Hitachi city, Ibaraki 316-8511, Japan
b Department of Biomolecular Functional Engineering, Faculty of Engineering, Ibaraki University Sciences and Engineering Material, 4-12-1, Nakanarusawa, Hitachi city, Ibaraki 316-8511, Japan
c FC Development CO., Ltd., 4-12-1, Nakanarusawa, Hitachi city, Ibaraki 316-8511, Japan
Abstract:The fuel cell transmogrified from a single cell that was the research object to stack is used in various fields such as cars, portable power sources, and fuel-cell cogeneration systems. It is preferable in the stack for the flow rate distribution between cells to be uniform because of the performance gain in power generation efficiency and longevity. As for the flow rate distribution between cells, the method for measuring using smoke in the measuring method and making visible the heat distribution in the stack is reported. However, a research stack was used with these measures, not a stack for practical use. In this report, a method for measuring the flow rate distribution between cells which can also be used for a cell that uses hydrogen limiting current in practical use was examined.
Keywords:PEFC   Stack   Flow rate distribution   Hydrogen limiting current
本文献已被 ScienceDirect 等数据库收录!