首页 | 本学科首页   官方微博 | 高级检索  
     

1.2 km标准基线环境参数自动测量系统研制
引用本文:刘学德,缪东晶,张京燕,李连福,李建双,张福民,李萍. 1.2 km标准基线环境参数自动测量系统研制[J]. 计量学报, 2020, 41(8): 897-902. DOI: 10.3969/j.issn.1000-1158.2020.08.01
作者姓名:刘学德  缪东晶  张京燕  李连福  李建双  张福民  李萍
作者单位:1.天津大学 精密仪器与光电子工程学院, 天津 300072
2.中国计量科学研究院, 北京 100029
基金项目:国家质检总局技术改造项目;国家重点研发计划
摘    要:为提高野外测量折射率补偿实时性,研制了1.2 km标准基线环境参数测量系统,该系统采用一种硬件分组和软件并行采集方案,将系统传感器数据采集的正确率提高到98%以上,82个传感器完整循环采集一次的时间小于7 s。计算出传感器7 s采样间隔温度变化量,分析评估折射率补偿结果,为野外标准基线测量提供科学的视角,量化寻找基线理想的测量时段,使延时温差小于0.05℃,高精度测距仪基线测量时的折射率修正误差控制在5×10-8内。

关 键 词:计量学  折射率修正  激光测距  环境参数  标准基线  自动测量系统  实时性  数据并行采集
收稿时间:2019-07-05

Development of Environmental Parameters Automatic Measurement System for 1.2km Standard Baseline
LIU Xue-de,MIAO Dong-jing,ZHANG Jing-yan,LI Lian-fu,LI Jian-shuang,ZHANG Fu-min,LI Ping. Development of Environmental Parameters Automatic Measurement System for 1.2km Standard Baseline[J]. Acta Metrologica Sinica, 2020, 41(8): 897-902. DOI: 10.3969/j.issn.1000-1158.2020.08.01
Authors:LIU Xue-de  MIAO Dong-jing  ZHANG Jing-yan  LI Lian-fu  LI Jian-shuang  ZHANG Fu-min  LI Ping
Affiliation:1. Precision Instruments & Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China
2. National Institute of Metrology, Beijing 100029, China
Abstract:To improve field measurement accuracy, the 1.2km standard baseline an environmental parameters automatic measurement system is developed, and a hardware grouping and software parallel acquisition scheme is adopted. The accuracy rate of sensor data acquisition in the system is more than 98%, and the time of complete cycle acquisition of 82 sensors is less than 7s. Calculate the temperature variation of sensor 7s sampling interval, analyze and evaluate the refractive index compensation results, provide a scientific perspective for field standard baseline measurement, quantify the ideal measurement period of baseline, make the delay temperature difference less than 0.05℃, the refractive index correction error of high precision rangefinder in baseline measurement is controlled within 5×10-8.
Keywords:metrology  refractive index correction  laser ranging  environmental parameter  automatic measurement system  standard baseline  real-time  data parallel acquisition  
本文献已被 万方数据 等数据库收录!
点击此处可从《计量学报》浏览原始摘要信息
点击此处可从《计量学报》下载全文