摘    要:阐述了水电站机组AGC与一次调频功能运行现状,并对4号机组进行试验分析,指出机组AGC与一次调频控制存在的配合缺陷,并对不匹配问题进行了优化改进.

关 键 词:一次调频  AGC  景洪水电站

Optimization of Primary Frequency Regulation and AGC in Unit of Jinghong Hydropower Station
HE Changsheng,SHU Rong,LIU Xingfu,DONG Hongkui,WU Yongzhi.Optimization of Primary Frequency Regulation and AGC in Unit of Jinghong Hydropower Station[J].Yunnan Electric Power,2014(1):106-109.
Authors:HE Changsheng  SHU Rong  LIU Xingfu  DONG Hongkui  WU Yongzhi
Affiliation:1. Yunnan Electric Power Grid Research Institute Kunming 650217 Yunnan China; 2. Huaneng Langcang River Hydropower CO. , LTD Kunming 650217 Yunnan China)
Abstract:The present situation of AGC and primary frequency regulation in the Jinghong hydropower station is described, test and Analysis on the No. 4 unit. The unit of Jinghong hydropower station AGC and primary frequency control in the match, and the mis- match problem is improved, to ensure that the AGC and the primary frequency modulation function of both the normal play a role.
Keywords:primary frequency regulation  Automatic Generation Control  Jinhong hydropower station