首页 | 本学科首页   官方微博 | 高级检索  
     

供水管道压力调控对漏水量影响的试验研究
引用本文:吴珊,刘彦辉,张申海,王维燕,马则中.供水管道压力调控对漏水量影响的试验研究[J].水利水电科技进展,2007,27(3):27-29.
作者姓名:吴珊  刘彦辉  张申海  王维燕  马则中
作者单位:1. 北京工业大学建筑工程学院,北京,100022
2. 北京市自来水集团公司供水分公司,北京,100034
摘    要:在某城市供水管网中,以消火栓模拟管道漏水点,利用减压阀在供水高压区进行管道压力调控,分析不同管径的管道压力变化对漏水量的影响,以及不同减压区间的漏水率降低效果。试验结果表明,压力管理是一种行之有效的漏损主动控制方法,利用减压方式供水在优化管网运行条件的同时,可以有效地减少管网漏水量;漏水量与管道压力呈指数规律变化,该指数随减压阀所安装管道的直径不同而异;降压减漏效果对相同管径的管道在高压区更有效,而对基本相同的压力降压范围,管径越大效果越明显。实际操作中采用何种减压方式及降压范围和管段须结合管网具体情况优化选择。

关 键 词:供水管网  漏水量  管道压力  压力调控
文章编号:1006-7647(2007)03-0027-03
修稿时间:2007-01-25

Experimental study on influences of pressure regulation and control in water supply pipes on volume of water leakage
WU Shan,LIU Yan-hui,ZHANG Shen-hai,WANG Wei-yan,MA Ze-zhong.Experimental study on influences of pressure regulation and control in water supply pipes on volume of water leakage[J].Advances in Science and Technology of Water Resources,2007,27(3):27-29.
Authors:WU Shan  LIU Yan-hui  ZHANG Shen-hai  WANG Wei-yan  MA Ze-zhong
Affiliation:1. College of Architecture Engineering, Beijing University of Technology, Beijing 100022, China; 2. Water Supply Branch of Beijing Waterworks Group, Beijing 100034, China
Abstract:With hydrants taken for leakage point simulation and relief valves used for pile pressure regulation and control in high-pressure areas in an urban water supply network, the influences of pressure variation in pipes with different diameters on the volume of water leakage and the effect of pressure relief range on the decrease of water leakage rate were analyzed. Test results show that the pressure regulation and control is an effective active method for water leakage control. The adoption of rehef valves decreased the water supply pressure and optimized the operational condition of pipes, and further effectively decreased the volume of water leakage. The volume of water leakage is of an exponential relationship with the pressure in pipes, and the exponent value varies with the diameter of pipes installed with rehef valves. The effect of pressure relief and leakage control of water supply pipes of the same diameter is better in high pressure region, however, as for the same pressure and pressure rebel range, the greater the pipe diameter, the better the effect of pressure rehef and leakage control. Moreover, the method of pressure relief as well as rational range and pipe section should be optimally chosen based on the practical situation.
Keywords:water supply network  volume of water leakage  pressure in pipeline  pressure regulation and control
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《水利水电科技进展》浏览原始摘要信息
点击此处可从《水利水电科技进展》下载全文