首页 | 本学科首页   官方微博 | 高级检索  
     

预包装食品中金黄色葡萄球菌3种鉴定方法的比较
引用本文:陈志敏,王金凤,孙晓霞,姜彦芬,王建昌. 预包装食品中金黄色葡萄球菌3种鉴定方法的比较[J]. 食品安全质量检测学报, 2020, 11(19): 7087-7092
作者姓名:陈志敏  王金凤  孙晓霞  姜彦芬  王建昌
作者单位:石家庄海关技术中心,石家庄海关技术中心,石家庄海关技术中心,石家庄海关技术中心,石家庄海关技术中心
摘    要:目的 比较国家标准方法(GB 4789.10-2016)、VITEK2 Compact全自动微生物鉴定系统、基质辅助激光解吸电离-飞行时间质谱法对预包装食品中金黄色葡萄球菌的鉴定效果。方法 使用金黄色葡萄球菌(ATCC 25923)人工污染12种不同种类的预包装食品,按照GB4789.10-2016进行样品前处理和增菌,通过上述三种方法对上述样品中分离的疑似金黄色葡萄球菌进行鉴定,并对鉴定结果进行比较。结果 三种方法均能够对12种不同种类的人工污染预包装食品中分离的金黄色葡萄球菌进行准确有效的鉴定。相对于国标法,两种仪器鉴定方法无需进行后续溶血分析和血浆凝固酶试验,对操作人员技术要求更低,能够在更短的时间内获得鉴定结果。结论 两种仪器鉴定方法快速、可靠且操作简单,可以作为国标法的有效补充。

关 键 词:金黄色葡萄球菌  食品安全国家标准  全自动微生物鉴定法  基质辅助激光解吸电离-飞行时间质谱法  鉴定
收稿时间:2020-06-08
修稿时间:2020-09-26

Comparison of 3 identification methods of Staphylococcus aureus in the prepackaged food
CHEN Zhi-Min,WANG Jin-Feng,SUN Xiao-Xi,JIANG Yan-Fen,WANG Jian-Chang. Comparison of 3 identification methods of Staphylococcus aureus in the prepackaged food[J]. Journal of Food Safety & Quality, 2020, 11(19): 7087-7092
Authors:CHEN Zhi-Min  WANG Jin-Feng  SUN Xiao-Xi  JIANG Yan-Fen  WANG Jian-Chang
Affiliation:Technology Center of Shijiazhuang Customs,Technology Center of Shijiazhuang Customs,Technology Center of Shijiazhuang Customs,Technology Center of Shijiazhuang Customs,Technology Center of Shijiazhuang Customs
Abstract:Objective To compare the identification effect of Staphylococcus aureus in 3 kinds of prepackaged food. Methods Twelve different kinds of prepackaged food were artificially contaminated with Staphylococcus aureus (ATCC 25923). According to the GB 4789.10-2016, the sample pretreatment and bacterial enrichment were performed. Furthermore, the suspected Staphylococcus aureus isolated from the above samples were identified by the national standard method, VITEK2 Compact and matrix assisted laser desorption/ionization -time of flight mass spectrometry (MALDI-TOF MS), and the identification results were compared. Results All suspicious colonies isolated from the 12 different kinds of artificial contaminated prepackaged food were identified as Staphylococcus aureus by the above three methods, and the results were consistent. Compared with the national standard method GB 4789.10-2016, the further hemolysis analysis and plasma coagulase test were unnecessary for the VITEK2 compact and MALDI-TOF MS. Furthermore, the technical requirements for operators were lower and the identification results could be obtained faster using the two automatic instrument methods. Conclusion The two identification methods using instruments are simpler to operate and faster to obtain the results, which could be used as an effective supplement to the current national standard method.
Keywords:Staphylococcus aureus   national food safety standard   VITEK2 Compact  matrix assisted laser desorption lonization-time of flight mass spectrometery   identification
点击此处可从《食品安全质量检测学报》浏览原始摘要信息
点击此处可从《食品安全质量检测学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号