摘    要:本文对漏电火灾报警系统的功用、适用场所与合理应用等进行概要的阐述,并对产品的选择从系统型式、产品功能和结构等方面进行分析,认为漏电火灾报警系统从功能和管理上应归于火灾自动报警系统。提出只要在适当的场所选择适用的产品,并遵循“有效、经济”的设计原则,漏电火灾报警系统对预防漏电火灾的发生能够起到一定的作用。

关 键 词:漏电火灾报警系统  漏电火灾的成因  适用场所  合理应用  产品选型

Rational Use of Residual Current Operated Fire Alarm System
Chen Jianbiao. Rational Use of Residual Current Operated Fire Alarm System[J]. Electrical Technology of Intelligent Buildings, 2006, 5(4): 8-30
Authors:Chen Jianbiao
Abstract:The paper introduces the functions of residual current operated fire alarm system, the places to where the system is applicable and the rational use of it, and analyzes on the products selection from the system type, products function and structure. The author puts forword that the residual current operated fire alarm system belongs to auto-alarm system on function and management, and the system can play a certain role in proventing from electric fire if proper products can be selected for the right places and follow the design principle of efficiency and economy.
Keywords:residual current operated fire alarm system   the cause of leakage fire   places being applicable   rational use   type selection of products