首页 | 本学科首页   官方微博 | 高级检索  
     

某电厂600MW机组叶片断裂分析
引用本文:訾壮辉,王梅英. 某电厂600MW机组叶片断裂分析[J]. 理化检验(物理分册), 2010, 0(7): 459-461
作者姓名:訾壮辉  王梅英
作者单位:[1]黑龙江省特种设备检验研究院,哈尔滨150036 [2]哈尔滨汽轮机厂有限责任公司,哈尔滨150046
摘    要:某电厂600 MW超超临界机组在检修中发现一只低压叶片断裂,采用宏观分析、金相检验以及断口分析等方法对叶片断裂原因进行了分析。结果表明:叶片服役环境中存在能够引起叶片材料产生腐蚀的氯离子,导致叶片发生腐蚀疲劳断裂。

关 键 词:叶片  腐蚀介质  腐蚀疲劳  断裂

Fracture Analysis of 600 MW Set Blade in Power Plant
ZI Zhuang-hui,WANG Mei-ying. Fracture Analysis of 600 MW Set Blade in Power Plant[J]. Physical Testing and Chemical Analysis Part A:Physical Testing, 2010, 0(7): 459-461
Authors:ZI Zhuang-hui  WANG Mei-ying
Affiliation:( Heilongjiang Special Equipment Test Institute, Harbin 150036, China; 2. Harbin Turbine Company, Harbin 150046, China)
Abstract:A low-pressure blade which used for the 600 MW super-hypercritic set of a power plant has fractured. The fracture reason was analyzed by means of macroscopic inspection, metallographic examination and fracture analysis. The results showed that the main reason caused blade fracture were that chlorine ions which can lead to corrosion existed in the working environment. And the fracture type of the blade was the corrosion fatigue fracture.
Keywords:blade  corrosive medium  corrosion fatigue  fracture