首页 | 本学科首页   官方微博 | 高级检索  
     

电抗耦合与不同期合闸对10kV并联电容器组合闸暂态的影响分析
引用本文:李历波,席世友,王贤亮,胡思国.电抗耦合与不同期合闸对10kV并联电容器组合闸暂态的影响分析[J].高压电器,2011,47(12):19-27.
作者姓名:李历波  席世友  王贤亮  胡思国
作者单位:重庆市电力公司綦南供电局,重庆,401420
摘    要:重庆市电力公司变电站近年来多次出现10 kV系统并联补偿电容器组合装置合闸过程中断路器(柜)故障事件.笔者从实际安装运行条件对合闸的过渡过程进行深入的理论分析:建立了1个含耦合电感的三相二阶电路模型,对该电路进行等效解耦和Laplace变换及反变换,分析了电感之间存在不对称耦合电感对三相电路过渡过程的影响;建立了含对地...

关 键 词:过电压  过电流  耦合电感  ATP-EMTP  二阶电路  仿真

Influence of Reactor Coupling and Asynchronous Closing on Transition Process of Closing Shunt Capacitors in 10 kV Power System
LI Li-bo,XI Shi-you,WANG Xian-liang,HU Si-guo.Influence of Reactor Coupling and Asynchronous Closing on Transition Process of Closing Shunt Capacitors in 10 kV Power System[J].High Voltage Apparatus,2011,47(12):19-27.
Authors:LI Li-bo  XI Shi-you  WANG Xian-liang  HU Si-guo
Abstract:To find out the reasons of the explosion of breakers while putting shunt compensation capacitor into operation in 10 kV power system,transition process of closing has been studied and discussed in depth in this paper.A new circuit model containing three-phase coupled inductors is established to analyze overvoltage and overcurrent in the transition of closing three-phase circuit breaker.Through decoupling and Laplace and inversely transforming the circuit,the influence of mutual inductance and different inductor polarities on the process of transition is discussed.In this paper,a new circuit model is established to analyze the over-voltage and overcurrent while breakers asynchronous closing.By selecting a set of practical operation 10 kV system parameters and taking numerical solution to it,cause of the higher overvoltage and overcurrent in the transition of asynchronously closing is investigated.ATP-EMTP Power System Simulation Software is employed into calculating the overvoltage and overcurrent with the actual parameters,the transition process under different situation of decoupling and breakers asynchronous closing is contrasted.The results prove that the breaker failure is more likely caused by the over-current.
Keywords:overvoltage  overcurrent  coupled inductors  ATP-EMTP  second order circuit  simulation