首页 | 本学科首页   官方微博 | 高级检索  
     

型钢高性能纤维混凝土粘结滑移性能试验研究
引用本文:明铭,郑山锁,郑淏,贺金川,董立国,宋明辰.型钢高性能纤维混凝土粘结滑移性能试验研究[J].工程力学,2020,37(8):148-157.
作者姓名:明铭  郑山锁  郑淏  贺金川  董立国  宋明辰
作者单位:1.西安建筑科技大学土木工程学院,陕西,西安 710055
基金项目:国家重点研发计划课题项目(2019YFC1509302);国家自然科学基金计划项目(51678475);西安市科技计划项目(2019113813CXSF016SF026);陕西省教育厅产业化项目(18JC020)
摘    要:为研究型钢与高性能纤维混凝土之间的粘结滑移性能,以高性能纤维混凝土强度、保护层厚度以及型钢锚固长度为变化参数,设计10个型钢高性能纤维混凝土试件,进而对其进行推出试验,观察试件的破坏过程和裂缝发展形态,获取试件的荷载-滑移曲线。基于试验结果,探讨了各设计参数对特征粘结强度的影响规律,并建立了特征粘结强度的计算公式。对有效粘结应力计算公式进行推导,得到有效粘结应力-滑移分布曲线,并对其进行全过程分析。结果表明:适当增加型钢保护层厚度和混凝土强度,能有效提高型钢高性能纤维混凝土的特征粘结强度;特征粘结强度计算值与试验值吻合较好,表明该文提出的计算公式具有较高的精度;有效粘结应力能够反映型钢与高性能纤维混凝土界面间粘结应力的发展变化过程,并得到粘结应力各组份之间的比例关系。研究成果可为型钢高性能纤维混凝土相关计算理论提供试验依据。

关 键 词:型钢混凝土结构    高性能纤维混凝土    推出试验    粘结强度    有效粘结应力
收稿时间:2019-09-21

EXPERIMENTAL STUDY ON BOND-SLIP BEHAVIOR BETWEEN ENCASED STEEL AND HIGH-PERFORMANCE-FIBER CONCRETE
Affiliation:1.School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, China2.Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education (XAUAT), Xi’an, Shaanxi 710055, China3.Architecture Design and Research Group of Xi’an University of Architecture and Technology, Xi’an, Shaanxi, 710055, China
Abstract:Ten push-out experimental specimens were cast and tested to study the interfacial bond-slip behavior of section steel and high-performance fiber concrete (HPFC). The main parameters investigated were strength grade, concrete cover thickness and embedded length. The failure process and load-slip (P-S) curves were obtained. The influence regularities of design parameters on the characteristic bond strength were studied, and the formulae of characteristic bond strength were established. The effective bond stress was introduced and deduced. Through the analysis of the whole process of the effective bond stress slip curve, the development of bond stress was obtained. The results show that : the characteristics bond strength were increased by the increase of the concrete cover thickness and the concrete strength; the calculated value of the characteristics bond strength appeared were similar to that of the test values; the effective bond stress reflected the development and transformation of bond stress at the interface between section steel and high-performance-fiber-concrete; the proportional relationship among the components of the bonding force was derived by process analysis. The research provides an experimental support for analyzing the mechanical behaviors of steel reinforced high-performance-fiber-concrete.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《工程力学》浏览原始摘要信息
点击此处可从《工程力学》下载全文