首页 | 本学科首页   官方微博 | 高级检索  
     


Influence of DOC on the Inactivation Efficiency of Ozonation Assessed with Clostridium perfringens and a Lab-Scale Continuous Flow System
Authors:W A M Hijnen  E Baars  T G J Bosklopper  A J Veer  R T Meijers  G J Medema
Affiliation:1. Kiwa Water Research Ltd. , Nieuwegein, the Netherlands;2. Amsterdam Water Supply , Amsterdam, the Netherlands;3. Water Company Europoort , Rotterdam, the Netherlands;4. Aquavisie , Hengelo, the Netherlands
Abstract:Routine quality monitoring for fecal indicators after ozonation at the river-lake waterworks Weesperkarspel of Amsterdam Water Supply (AWS) show large variation in inactivation. The influence of the high DOC in the water on the inactivation efficiency was investigated. Results showed a higher inactivation of Clostridium perfringens in the AWS water than in a water with low DOC at the same CT conditions. The contribution of the gas feed chamber to the overall inactivation of C. perfringens was high in the AWS water and was reduced after DOC reduction with GAC. This result may alter the current CT concept of the process. Further research will be focused on the ozone dosage strategy and control related to the required CT for inactivation and the production of by-products.
Keywords:Ozone  inactivation  Clostridium perfringens  Bacillus subtilis  Escherichia coli  DOC and gas feed chamber